---
title: "Grow Tent Fan Size Calculator: CFM, Negative Pressure, and the Implosion Risk Nobody Talks About"
canonical: "https://theyieldgrid.com/grow-tent-fan-size-calculator/"
model_id: "tyg-728"
model_version: "1.0.0"
last_reviewed: "2026-08-20T11:01:31"
reviewed_by: "Umer Hayiat"
---

# Grow Tent Fan Size Calculator: CFM, Negative Pressure, and the Implosion Risk Nobody Talks About

> Canonical calculator: [https://theyieldgrid.com/grow-tent-fan-size-calculator/](https://theyieldgrid.com/grow-tent-fan-size-calculator/)

## What this calculator does

Home - Free Gardening Calculators & Tools - Grow Tent Fan Size Calculator: CFM, Negative Pressure, and the Implosion Risk Nobody Talks About Prevent tent implosion · Size your exhaust fan correctly · Maintain negative pressure

## Inputs

| Input | ID | Type | Unit | Range or choices | Required |
|---|---|---|---|---|---|
| Tent Length * | `gtcfm_length` | number |  | 1 to 50 | Yes |
| Tent Width * | `gtcfm_width` | number |  | 1 to 50 | Yes |
| Tent Height * | `gtcfm_height` | number |  | 1 to 20 | Yes |
| Grow Light Wattage * | `gtcfm_watts` | number | LEDs, HPS, CMH | 0 to 10000 | Yes |
| Ducting Length * | `gtcfm_ducting` | number | both tent-in and tent-out | 0 to 200 | Yes |
| Number of 90° Bends * | `gtcfm_bends` | number |  | 0 to 20 | Yes |
| ✓ Yes — Filter Attached | `gtcfm_filter_yes` | radio |  |  | No |
| ✗ No Filter | `gtcfm_filter_no` | radio |  |  | No |

## Outputs

| Output ID | Default state |
|---|---|
| `gtcfm_length_err` |  |
| `gtcfm_width_err` |  |
| `gtcfm_height_err` |  |
| `gtcfm_watts_err` |  |
| `gtcfm_ducting_err` |  |
| `gtcfm_bends_err` |  |
| `gtcfm_results` | Minimum Fan Size Required — CFM (Cubic Feet per Minute) Undersized Ideal Zone Oversized TENT IMPLOSION WARNING — Minimum Passive Intake Required 🏠 Tent Volume (L × W × H) 💨 Base CFM (volume ÷ 3 min air exchange) 🌡️ Heat Load CFM (lights × 3.41 BTU/W ÷ 1.1 ΔT) 🔩 Carbon Filter Penalty (+20%) ↪️ Ducting + Bends Penalty ✓ Total Required CFM ⚠ Warnings & Safety Standards 📊 Your Tent’s CFM Reference Table (live computed) Scenario CFM Needed Status Recommended Equipment for Your Setup AC Infinity Cloud |
| `gtcfm_out_primary` | — |
| `gtcfm_gauge_status` |  |
| `gtcfm_out_volume` |  |
| `gtcfm_out_base` |  |
| `gtcfm_out_heat` |  |
| `gtcfm_out_filter` |  |
| `gtcfm_out_duct` |  |
| `gtcfm_out_total` |  |
| `gtcfm_warnings_box` | ⚠ Warnings & Safety Standards |

## Formula and method

Show the calculation steps Step 1: Tent Volume Volume = Length x Width x Height (all in feet, result in cubic feet) Step 2: Base CFM (Air Exchange Rate) Base CFM = Volume / 3 This targets one complete air exchange every 3 minutes, which is the standard rate for high-transpiration crops. The divisor changes the exchange interval: Volume / 1 gives one exchange per minute for aggressive hot climates; Volume / 5 is the minimum acceptable for cool, dry setups. Step 3: Heat Load CFM BTU per hour = Watts x 3.41 (the thermal equivalency factor for electrical energy) Heat CFM = BTU_per_hour / (1.1 x 20) The 1.1 factor comes from the sensible heat constant for air at standard conditions. The 20 is the assumed acceptable temperature rise in degrees Fahrenheit. A 20 degree F rise (roughly 11 degrees C) means the exhausted air is 20 degrees warmer than incoming air. If your ambient room runs hot already and you want a tighter rise of 10 degrees F, double the Heat CFM value before proceeding. Step 4: Resistance Penalties Carbon filter penalty: add 20% to the combined (Base + Heat) CFM Each 90-degree bend: add 15% per bend Total penalty multiplier = 1 + 0.20 (if filter) + (bends x 0.15) Step 5: Total Required CFM Total = (Base CFM + Heat CFM) x Total Penalty Multiplier Result is rounded up to the nearest whole CFM. This is the minimum at which a fan must perform under your actual system resistance, not the fan’s free-air rating. Rounding rule: Always round up (ceiling). A fan specified at 191.2 CFM should be replaced with one rated at 192 CFM minimum, then further buffered upward for real-world derating. Assumptions and Limits The 3-minute air exchange rate is appropriate for cannabis and other high-transpiration crops. Seedling rooms, cloning chambers, or cooler setups may tolerate a 4-5 minute exchange; adjust manually by using a shorter interval in your volume calculation. The 20-degree F temperature differential is a conservative midpoint. In a climate-controlled room where incoming air is already conditioned, this differential may be acceptable at 15 degrees. In a hot garage or attic space in summer, it may need to drop to 10 degrees, which doubles the heat load CFM output. LED fixtures are assumed to emit full wattage as heat. In practice, quality quantum board LEDs convert roughly 40-50% of input power to usable photons rather than heat. Using full wattage is conservative and safe; if you have manufacturer thermal data showing a lower heat fraction, you may reduce the wattage input by that fraction. The 15% bend penalty is based on ASHRAE equivalent duct length methods for smooth rigid elbows. Flexible aluminum duct kinked at a 90-degree angle produces higher losses, sometimes 20-25%. The calculator is conservative for rigid duct; it may underestimate losses for kinked flex duct. Straight duct run length contributes friction loss but at a much lower rate than bends. Runs under 25 feet contribute losses smaller than the inherent uncertainty in manufacturer CFM ratings, so they are captured in the recommended purchase buffer rather than a separate formula term. The tool does not account for altitude. At 5,000 feet elevation, air density is roughly 17% lower, meaning your fan moves the same volume but with less mass, reducing heat transfer capacity. Add 10-15% to your calculated CFM if growing above 3,500 feet. CO2 enrichment systems in sealed rooms require different airflow logic; this calculator is designed for negative-pressure tents exchanging air with the room, not sealed recirculation setups.

## Verified worked examples

### Example 1: Small Starter Setup (2x2x4 ft, 200W LED, No Filter)

Length: 2 ft, Width: 2 ft, Height: 4 ft Tent Volume: 2 x 2 x 4 = 16 ft³ Grow Light Wattage: 200W actual draw Carbon Filter: No Ducting Length: 6 ft, Bends: 1 Base CFM = 16 / 3 = 5.3 CFM Heat Load = (200 x 3.41) / (1.1 x 20) = 682 / 22 = 31.0 CFM Bend Penalty = 1 x 15% = 15% Total = (5.3 + 31.0) x (1 + 0.15) = 36.3 x 1.15 = 41.7 CFM Result: 42 CFM minimum. A 4-inch inline fan rated at 50-60 CFM handles this setup with appropriate headroom. The heat load dominates because the tent volume is small relative to light power, a pattern common in 2×2 setups.

### Example 2: Standard 4×4 with HPS and Carbon Filter (4x4x6.5 ft, 600W, Filter On, 2 Bends)

Length: 4 ft, Width: 4 ft, Height: 6.5 ft Tent Volume: 4 x 4 x 6.5 = 104 ft³ Grow Light Wattage: 600W Carbon Filter: Yes (+20%) Ducting Length: 10 ft, Bends: 2 Base CFM = 104 / 3 = 34.7 CFM Heat Load = (600 x 3.41) / 22 = 2046 / 22 = 93.0 CFM Penalty = 20% (filter) + 30% (2 bends) = 50% Total = (34.7 + 93.0) x 1.50 = 127.7 x 1.50 = 191.5 CFM Result: 192 CFM minimum. A 6-inch fan rated at 220-250 CFM is appropriate. Note that without the filter and bends, the bare number would be 128 CFM — a grower who skips the penalty math and buys a 150 CFM fan ends up chronically undersized.

### Example 3: Large Multi-Light Tent (5x9x8 ft, 1500W, Filter On, 4 Bends)

Length: 5 ft, Width: 9 ft, Height: 8 ft Tent Volume: 5 x 9 x 8 = 360 ft³ Grow Light Wattage: 1500W combined Carbon Filter: Yes (+20%) Ducting Length: 18 ft, Bends: 4 Base CFM = 360 / 3 = 120 CFM Heat Load = (1500 x 3.41) / 22 = 5115 / 22 = 232.5 CFM Penalty = 20% (filter) + 60% (4 bends) = 80% Total = (120 + 232.5) x 1.80 = 352.5 x 1.80 = 634.5 CFM Result: 635 CFM minimum. At this level, a single 8-inch fan rated at 750+ CFM is appropriate, or two 6-inch fans in parallel. With 4 bends at 80% combined penalty, rerouting even one bend saves roughly 53 CFM of required capacity — equivalent to dropping from an 8-inch to a slightly smaller unit.

## Assumptions

Length: 4 ft, Width: 4 ft, Height: 6.5 ft Tent Volume: 4 x 4 x 6.5 = 104 ft³ Grow Light Wattage: 600W Carbon Filter: Yes (+20%) Ducting Length: 10 ft, Bends: 2 Base CFM = 104 / 3 = 34.7 CFM Heat Load = (600 x 3.41) / 22 = 2046 / 22 = 93.0 CFM Penalty = 20% (filter) + 30% (2 bends) = 50% Total = (34.7 + 93.0) x 1.50 = 127.7 x 1.50 = 191.5 CFM Result: 192 CFM minimum. A 6-inch fan rated at 220-250 CFM is appropriate. Note that without the filter and bends, the bare number would be 128 CFM — a grower who skips the penalty math and buys a 150 CFM fan ends up chronically undersized. Show the calculation steps Step 1: Tent Volume Volume = Length x Width x Height (all in feet, result in cubic feet) Step 2: Base CFM (Air Exchange Rate) Base CFM = Volume / 3 This targets one complete air exchange every 3 minutes, which is the standard rate for high-transpiration crops. The divisor changes the exchange interval: Volume / 1 gives one exchange per minute for aggressive hot climates; Volume / 5 is the minimum acceptable for cool, dry setups. Step 3: Heat Load CFM BTU per hour = Watts x 3.41 (the thermal equivalency factor for electrical energy) Heat CFM = BTU_per_hour / (1.1 x 20) The 1.1 factor comes from the sensible heat constant for air at standard conditions. The 20 is the assumed acceptable temperature rise in degrees Fahrenheit. A 20 degree F rise (roughly 11 degrees C) means the exhausted air is 20 degrees warmer than incoming air. If your ambient room runs hot already and you want a tighter rise of 10 degrees F, double the Heat CFM value before proceeding. Step 4: Resistance Penalties Carbon filter penalty: add 20% to the combined (Base + Heat) CFM Each 90-degree bend: add 15% per bend Total penalty multiplier = 1 + 0.20 (if filter) + (bends x 0.15) Step 5: Total Required CFM Total = (Base CFM + Heat CFM) x Total Penalty Multiplier Result is rounded up to the nearest whole CFM. This is the minimum at which a fan must perform under your actual system resistance, not the fan’s free-air rating. Rounding rule: Always round up (ceiling). A fan specified at 191.2 CFM should be replaced with one rated at 192 CFM minimum, then further buffered upward for real-world derating. Assumptions and Limits The 3-minute air exchange rate is appropriate for cannabis and other high-transpiration crops. Seedling rooms, cloning chambers, or cooler setups may tolerate a 4-5 minute exchange; adjust manually by using a shorter interval in your volume calculation. The 20-degree F temperature differential is a conservative midpoint. In a climate-controlled room where incoming air is already conditioned, this differential may be acceptable at 15 degrees. In a hot garage or attic space in summer, it may need to drop to 10 degrees, which doubles the heat load CFM output. LED fixtures are assumed to emit full wattage as heat. In practice, quality quantum board LEDs convert roughly 40-50% of input power to usable photons rather than heat. Using full wattage is conservative and safe; if you have manufacturer thermal data showing a lower heat fraction, you may reduce the wattage input by that fraction. The 15% bend penalty is based on ASHRAE equivalent duct length methods for smooth rigid elbows. Flexible aluminum duct kinked at a 90-degree angle produces higher losses, sometimes 20-25%. The calculator is conservative for rigid duct; it may underestimate losses for kinked flex duct. Straight duct run length contributes friction loss but at a much lower rate than bends. Runs under 25 feet contribute losses smaller than the inherent uncertainty in manufacturer CFM ratings, so they are captured in the recommended purchase buffer rather than a separate formula term. The tool does not account for altitude. At 5,000 feet elevation, air density is roughly 17% lower, meaning your fan moves the same volume but with less mass, reducing heat transfer capacity. Add 10-15% to your calculated CFM if growing above 3,500 feet. CO2 enrichment systems in sealed rooms require different airflow logic; this calculator is designed for negative-pressure tents exchanging air with the room, not sealed recirculation setups. The 3-minute air exchange rate is appropriate for cannabis and other high-transpiration crops. Seedling rooms, cloning chambers, or cooler setups may tolerate a 4-5 minute exchange; adjust manually by using a shorter interval in your volume calculation. The 20-degree F temperature differential is a conservative midpoint. In a climate-controlled room where incoming air is already conditioned, this differential may be acceptable at 15 degrees. In a hot garage or attic space in summer, it may need to drop to 10 degrees, which doubles the heat load CFM output. LED fixtures are assumed to emit full wattage as heat. In practice, quality quantum board LEDs convert roughly 40-50% of input power to usable photons rather than heat. Using full wattage is conservative and safe; if you have manufacturer thermal data showing a lower heat fraction, you may reduce the wattage input by that fraction. The 15% bend penalty is based on ASHRAE equivalent duct length methods for smooth rigid elbows. Flexible aluminum duct kinked at a 90-degree angle produces higher losses, sometimes 20-25%. The calculator is conservative for rigid duct; it may underestimate losses for kinked flex duct. Straight duct run length contributes friction loss but at a much lower rate than bends. Runs under 25 feet contribute losses smaller than the inherent uncertainty in manufacturer CFM ratings, so they are captured in the recommended purchase buffer rather than a separate formula term. The tool does not account for altitude. At 5,000 feet elevation, air density is roughly 17% lower, meaning your fan moves the same volume but with less mass, reducing heat transfer capacity. Add 10-15% to your calculated CFM if growing above 3,500 feet. CO2 enrichment systems in sealed rooms require different airflow logic; this calculator is designed for negative-pressure tents exchanging air with the room, not sealed recirculation setups. Testing the physical result of your Grow Tent CFM Calculator output ensures the tent walls hold steady without collapsing inward. Critical Warnings Tent implosion is a mechanical failure, not just reduced airflow. When exhaust capacity significantly exceeds available intake area, the pressure differential across the tent fabric becomes structurally damaging. Tent walls snap inward, poles can buckle, and plants in the path of collapsing fabric sustain physical damage. The minimum intake area displayed by the calculator is not a suggestion; it is the threshold below which structural failure becomes likely at fan operating speed. Manufacturer CFM ratings are measured at zero static pressure. No real installation has zero static pressure. With a carbon filter and two bends, a fan rated at 200 CFM may deliver 130-150 CFM under actual conditions. Always specify a fan that meets your calculated requirement at the static pressure your system actually produces, or apply a minimum 15% buffer above the free-air rated CFM when a manufacturer does not publish static pressure curves. A speed controller that reduces fan speed to its minimum setting can push the system into undersized territory. If you plan to run a large fan at 20-30% speed to reduce noise, verify that the delivered CFM at that setting still meets the calculated minimum. Smart controllers with tachometer feedback (such as the AC Infinity controller series) make this verification possible; basic triac dimmers do not. Carbon filter resistance increases as the media loads with activated carbon particles and particulate buildup. A filter that adds 20% resistance when new may add 35-40% near the end of its service life. Re-running this calculator with a higher penalty estimate toward the end of a filter’s life helps identify whether a speed increase or filter replacement is the limiting factor. Minimum Standards At least one complete air exchange every 3 minutes during the lights-on period for high-transpiration crops. Passive intake area must equal or exceed the calculated minimum (Total CFM / 144 in square feet) to keep negative pressure in the functional range rather than the damaging range. Fan purchase rating should be at least 15% above the calculated Total Required CFM to account for real-world derating under static pressure. Duct runs with 4 or more 90-degree bends should be reviewed for rerouting; the combined 60%+ penalty at that count frequently makes fan upgrade a false economy compared to simplifying the duct path. Competitor Trap: Many grow tent ventilation guides stop at “CFM equals tent volume divided by one to three minutes.” That formula produces a number that accounts only for air exchange and completely ignores the two largest variables in a real installation: grow light heat load and system resistance. A 4×4 tent with a 600W HPS light and a carbon filter needs roughly 190 CFM — more than 4x the bare air-exchange figure of 35 CFM. Growers who follow the simplified formula buy undersized fans, then compensate by running lights at reduced power or adding portable AC units, neither of which addresses the root calculation error. Airflow interacts closely with humidity management. A correctly sized exhaust fan removes both heat and water vapor, but in rooms with high ambient humidity, the exhaust may not fully manage vapor pressure deficit on its own. The VPD calculator helps you determine whether your airflow is controlling the vapor pressure differential your crop stage requires, or whether a supplemental dehumidifier is necessary. For heat load calculations that extend beyond exhaust sizing into full HVAC planning, the grow room AC sizing calculator takes the same light wattage inputs and extends them to BTU-per-hour cooling requirements for air conditioning unit selection. At least one complete air exchange every 3 minutes during the lights-on period for high-transpiration crops. Passive intake area must equal or exceed the calculated minimum (Total CFM / 144 in square feet) to keep negative pressure in the functional range rather than the damaging range. Fan purchase rating should be at least 15% above the calculated Total Required CFM to account for real-world derating under static pressure. Duct runs with 4 or more 90-degree bends should be reviewed for rerouting; the combined 60%+ penalty at that count frequently makes fan upgrade a false economy compared to simplifying the duct path. Competitor Trap: Many grow tent ventilation guides stop at “CFM equals tent volume divided by one to three minutes.” That formula produces a number that accounts only for air exchange and completely ignores the two largest variables in a real installation: grow light heat load and system resistance. A 4×4 tent with a 600W HPS light and a carbon filter needs roughly 190 CFM — more than 4x the bare air-exchange figure of 35 CFM. Growers who follow the simplified formula buy undersized fans, then compensate by running lights at reduced power or adding portable AC units, neither of which addresses the root calculation error. Airflow interacts closely with humidity management. A correctly sized exhaust fan removes both heat and water vapor, but in rooms with high ambient humidity, the exhaust may not fully manage vapor pressure deficit on its own. The VPD calculator helps you determine whether your airflow is controlling the vapor pressure differential your crop stage requires, or whether a supplemental dehumidifier is necessary. For heat load calculations that extend beyond exhaust sizing into full HVAC planning, the grow room AC sizing calculator takes the same light wattage inputs and extends them to BTU-per-hour cooling requirements for air conditioning unit selection.

## Limitations and safety

The 3-minute air exchange rate is appropriate for cannabis and other high-transpiration crops. Seedling rooms, cloning chambers, or cooler setups may tolerate a 4-5 minute exchange; adjust manually by using a shorter interval in your volume calculation. The 20-degree F temperature differential is a conservative midpoint. In a climate-controlled room where incoming air is already conditioned, this differential may be acceptable at 15 degrees. In a hot garage or attic space in summer, it may need to drop to 10 degrees, which doubles the heat load CFM output. LED fixtures are assumed to emit full wattage as heat. In practice, quality quantum board LEDs convert roughly 40-50% of input power to usable photons rather than heat. Using full wattage is conservative and safe; if you have manufacturer thermal data showing a lower heat fraction, you may reduce the wattage input by that fraction. The 15% bend penalty is based on ASHRAE equivalent duct length methods for smooth rigid elbows. Flexible aluminum duct kinked at a 90-degree angle produces higher losses, sometimes 20-25%. The calculator is conservative for rigid duct; it may underestimate losses for kinked flex duct. Straight duct run length contributes friction loss but at a much lower rate than bends. Runs under 25 feet contribute losses smaller than the inherent uncertainty in manufacturer CFM ratings, so they are captured in the recommended purchase buffer rather than a separate formula term. The tool does not account for altitude. At 5,000 feet elevation, air density is roughly 17% lower, meaning your fan moves the same volume but with less mass, reducing heat transfer capacity. Add 10-15% to your calculated CFM if growing above 3,500 feet. CO2 enrichment systems in sealed rooms require different airflow logic; this calculator is designed for negative-pressure tents exchanging air with the room, not sealed recirculation setups. Testing the physical result of your Grow Tent CFM Calculator output ensures the tent walls hold steady without collapsing inward. Critical Warnings Tent implosion is a mechanical failure, not just reduced airflow. When exhaust capacity significantly exceeds available intake area, the pressure differential across the tent fabric becomes structurally damaging. Tent walls snap inward, poles can buckle, and plants in the path of collapsing fabric sustain physical damage. The minimum intake area displayed by the calculator is not a suggestion; it is the threshold below which structural failure becomes likely at fan operating speed. Manufacturer CFM ratings are measured at zero static pressure. No real installation has zero static pressure. With a carbon filter and two bends, a fan rated at 200 CFM may deliver 130-150 CFM under actual conditions. Always specify a fan that meets your calculated requirement at the static pressure your system actually produces, or apply a minimum 15% buffer above the free-air rated CFM when a manufacturer does not publish static pressure curves. A speed controller that reduces fan speed to its minimum setting can push the system into undersized territory. If you plan to run a large fan at 20-30% speed to reduce noise, verify that the delivered CFM at that setting still meets the calculated minimum. Smart controllers with tachometer feedback (such as the AC Infinity controller series) make this verification possible; basic triac dimmers do not. Carbon filter resistance increases as the media loads with activated carbon particles and particulate buildup. A filter that adds 20% resistance when new may add 35-40% near the end of its service life. Re-running this calculator with a higher penalty estimate toward the end of a filter’s life helps identify whether a speed increase or filter replacement is the limiting factor. Minimum Standards At least one complete air exchange every 3 minutes during the lights-on period for high-transpiration crops. Passive intake area must equal or exceed the calculated minimum (Total CFM / 144 in square feet) to keep negative pressure in the functional range rather than the damaging range. Fan purchase rating should be at least 15% above the calculated Total Required CFM to account for real-world derating under static pressure. Duct runs with 4 or more 90-degree bends should be reviewed for rerouting; the combined 60%+ penalty at that count frequently makes fan upgrade a false economy compared to simplifying the duct path. Competitor Trap: Many grow tent ventilation guides stop at “CFM equals tent volume divided by one to three minutes.” That formula produces a number that accounts only for air exchange and completely ignores the two largest variables in a real installation: grow light heat load and system resistance. A 4×4 tent with a 600W HPS light and a carbon filter needs roughly 190 CFM — more than 4x the bare air-exchange figure of 35 CFM. Growers who follow the simplified formula buy undersized fans, then compensate by running lights at reduced power or adding portable AC units, neither of which addresses the root calculation error. Airflow interacts closely with humidity management. A correctly sized exhaust fan removes both heat and water vapor, but in rooms with high ambient humidity, the exhaust may not fully manage vapor pressure deficit on its own. The VPD calculator helps you determine whether your airflow is controlling the vapor pressure differential your crop stage requires, or whether a supplemental dehumidifier is necessary. For heat load calculations that extend beyond exhaust sizing into full HVAC planning, the grow room AC sizing calculator takes the same light wattage inputs and extends them to BTU-per-hour cooling requirements for air conditioning unit selection.

## Related calculators

- [Calculators & Tools](https://theyieldgrid.com/category/garden-calculators/)
- [greenhouse fan calculator](https://theyieldgrid.com/greenhouse-fan-calculator/)
- [carbon filter sizing calculator](https://theyieldgrid.com/grow-room-carbon-filter-sizing/)
- [VPD calculator](https://theyieldgrid.com/vpd-calculator/)
- [grow room AC sizing calculator](https://theyieldgrid.com/grow-room-ac-sizing-btu/)
- [dehumidifier sizing tool](https://theyieldgrid.com/grow-room-dehumidifier-calculator/)
- [CO2 requirements calculator](https://theyieldgrid.com/co2-calculator/)
- [grow light energy cost tool](https://theyieldgrid.com/grow-light-cost-calculator/)
- [dew point calculator](https://theyieldgrid.com/dew-point-calculator/)
- [Prev Previous](https://theyieldgrid.com/growing-degree-days-calculator/)
- [Next Next](https://theyieldgrid.com/fungicide-frac-code-calculator/)

## Provenance

- Model ID: `tyg-728`
- Model version: `1.0.0`
- Reviewed by: Umer Hayiat
- Page modified: 2026-08-20T11:01:31
- Runtime SHA-256: `543cae7a706cf6ce8e57dbc017b5499f4fb6bde2d848a4b195ed659381a5576f`

This Markdown document is a machine-readable mirror. The canonical interactive calculator is the HTML page linked above.
